All-in-one Table Top
All in one solution
The all-in-one residential energy storage solution (ESS) delivers seamless and intelligent power management for modern
homes. Engineered for exceptional reliability and performance, it combines a hybrid inverter, scalable lithium iron
phosphate (LiFePO4) battery technology, and advanced energy optimization features into a single, integrated system.
KEY FEATURES
Integrated solution
All-in-one design with hybrid inverter and modular battery storage.
Life Cycle
3000+ charge cycles with a 5-year warranty.
Superior durability & safety
Supports peak shaving, scheduled charging, and other grid services using safe, long lasting lithium iron phosphate (LFP) battery chemistry.
Installation
Wall-mounted or tabletop configuration for flexible setup and reliable backup power during outages.

Technical Specifications
Parameter | Rating |
---|---|
Model Number | 2000VA/25.6 |
Nominal DC Voltage (V) | 25.6 |
MPPT Charger | |
Type of Charger | MPPT |
No of MPPT Channels | 1 |
Max. Connected PV Modules kW | 2.2 |
Max MPPT Output Current / Max Battery Charging Current (A) | 70 |
Max. Open Circuit PV Voltage (V) | 110 |
MPPT Voltage Range (V) | 35–88 |
MPPT Peak Efficiency | >94% |
Solar Inverter | |
Input Power at Peak Load (W) | 2200 |
Nominal Output Voltage (V) | 220 |
Nominal Output Frequency (Hz) | 50 |
Output Supply Phase | Single Phase |
Overloads |
100–125% – 120Sec 126–150% – 60Sec 151–200% – 5 Sec >200% – Immediate |
Output Type | Pure Sine Wave |
Input Source | PV/Battery/Grid |
Peak Inverter Efficiency | >85% |
THD | >5% |
Load Power Factor | 0.8 |
Battery | |
Battery (Ah)/(Voltage V) | 100/25.6 |
Battery (Wh) | 2560 |
Charging Current (A) | 30 |
Discharging Current (A) | 50 |
Max Continuous Discharging Current (A) | 100 |
Battery Under Cut Alarm (V) | 24.2 (Settable) |
Battery Under Cut (V) | 24 (Settable) |
Float Charging Voltage (V) | 28.8 |
Boost Charging Voltage (V) | 28.8 |
Grid Charger | |
Grid Operating Voltage Range (V) | 120–280 |
Grid Frequency Range | 47–53 |
Ambient Conditions | |
Operating Temp (°C) | 0–50 |
Humidity | 95% |
Degree of Protection | IP 20 |
Cooling Method | Temp. Controlled FAN Force Cooling |
Display/Indication | |
Protections |
PV – Reverse Polarity, High Current Battery – Reverse Polarity, Under Voltage Cut, Over Voltage Cut Grid – Over/Under Voltage, Over/Under Freq., Surge Protection, Reverse Feed Protection Load – Overload, Short Circuit |
Display Parameters |
PV: Voltage, Amps, Power, Today KWH, Total KWH Generation. Battery: Voltage, Amps, Charge/Discharge Status Grid: Voltage, Frequency Load: Voltage, Load%, Frequency. Load Operating Modes (UPS/Wide Range), Priority Selection, Grid Charging Enable/Disable, Battery Status (Charging/Discharging) |
Display Faults |
PV: PV Over Voltage Battery: Battery Under Voltage, Battery Over Voltage Grid: Back Feed, Under/Over Voltage, Fuse Fail Load: Overload, O/P Short Circuit |