Grid Tie Inverter
Grid-tie inverter connects solar systems directly to the utility grid (230/400V) without a transformer.
Featuring an LCD display and easy controls, it simplifies operation and maintenance, especially in remote areas. With
MPPT technology for optimal energy conversion and safety features like anti-islanding protection, it ensures reliable and
efficient power management for both residential and commercial systems.
KEY FEATURES
- 1MPPT tracker, Max Efficiency upto 97.5%
- Zero Export Application, VSG application
- String intelligent monitoring (optional)
- Wide output voltage range
- Anti-PID function (Optional)
- Low start-up voltage of 80V

Technical Specifications
Model Name | CLN-GTI-1000 | CLN-GTI-1500 | CLN-GTI-2000 | CLN-GTI-3000 | CLN-GTI-4000 | CLN-GTI-5000 |
---|---|---|---|---|---|---|
PV String Input Data | ||||||
Max. PV Input Power (kW) | 1.3 | 2 | 2.6 | 3.9 | 5.2 | 7.5 |
Max. PV Input Voltage (Vdc) | 550 | 600 | ||||
Start-up Voltage (V) | 80 | |||||
MPPT Voltage Range (Vdc) | 70–500 | |||||
Rated PV Input Voltage (V) | 360 | 420 | ||||
Max. Operating PV Input Current (A) | 20 | |||||
Max. Input Short Circuit Current (A) | 30 | |||||
No. of MPPT Trackers / Strings per Tracker | 1/1 | |||||
AC Output Side | ||||||
Rated AC Output Active Power (kW) | 1 | 1.5 | 2 | 3 | 4 | 5 |
Max. AC Output Apparent Power (kVA) | 1.1 | 1.65 | 2.2 | 3.3 | 4.4 | 5.5 |
Max. AC Output Current (A) | 5 / 4.8 | 7.5 / 7.2 | 10 / 9.6 | 15 / 14.4 | 20 / 19.2 | 25 / 24 |
Rated Output Voltage / Range (V) | 220 / 230V 0.85Un–1.1Un | |||||
Grid Connection Form | L / N / PE | |||||
Rated Output Grid Frequency / Range (Hz) | 50 / 45–55, 60 / 55–65 | |||||
Power Factor Adjustment Range | 0.8 Leading to 0.8 Lagging | |||||
Total Harmonic Distortion THDi | <3% | |||||
DC Injection Current | <0.5% In | |||||
Efficiency | ||||||
Max. Efficiency | 97.50% | |||||
Euro Efficiency | 97.00% | |||||
MPPT Efficiency | >99% | |||||
Equipment Protection | ||||||
DC Polarity Reverse Connection Protection | YES | |||||
Thermal Protection | YES | |||||
Earth Fault Detection | YES | |||||
Over Voltage Load Drop Protection | YES | |||||
Residual Current (RCD) Detection | YES | |||||
Interface | ||||||
Communication Interface | RS485 / RS232 | |||||
Monitor Mode | GPRS / WIFI / Bluetooth / 4G / LAN (optional) | |||||
General Data | ||||||
Operating Temperature Range (°C) | (-10 to +60°C, >45°C De-rating) | |||||
Permissible Ambient Humidity | 0–100% | |||||
Permissible Altitude (m) | 4000 | |||||
Ingress Protection (IP) Rating | IP65 | |||||
Inverter Topology | Non-Isolated | |||||
Type of Cooling | Natural Cooling | |||||
Grid Regulation | IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105 | |||||
Safety EMC / Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |