All-in-one Table Top

All in one solution

The all-in-one residential energy storage solution (ESS) delivers seamless and intelligent power management for modern
homes. Engineered for exceptional reliability and performance, it combines a hybrid inverter, scalable lithium iron
phosphate (LiFePO4) battery technology, and advanced energy optimization features into a single, integrated system.

KEY FEATURES

Integrated solution

All-in-one design with hybrid inverter and modular battery storage.

Life Cycle

3000+ charge cycles with a 5-year warranty.

Superior durability & safety

Supports peak shaving, scheduled charging, and other grid services using safe, long lasting lithium iron phosphate (LFP) battery chemistry.

Installation

Wall-mounted or tabletop configuration for flexible setup and reliable backup power during outages.

Technical Specifications

Responsive Table with Custom First Column Width
Parameter Rating
Model Number2000VA/25.6
Nominal DC Voltage (V)25.6
MPPT Charger
Type of ChargerMPPT
No of MPPT Channels1
Max. Connected PV Modules kW2.2
Max MPPT Output Current / Max Battery Charging Current (A)70
Max. Open Circuit PV Voltage (V)110
MPPT Voltage Range (V)35–88
MPPT Peak Efficiency>94%
Solar Inverter
Input Power at Peak Load (W)2200
Nominal Output Voltage (V)220
Nominal Output Frequency (Hz)50
Output Supply PhaseSingle Phase
Overloads 100–125% – 120Sec
126–150% – 60Sec
151–200% – 5 Sec
>200% – Immediate
Output TypePure Sine Wave
Input SourcePV/Battery/Grid
Peak Inverter Efficiency>85%
THD>5%
Load Power Factor0.8
Battery
Battery (Ah)/(Voltage V)100/25.6
Battery (Wh)2560
Charging Current (A)30
Discharging Current (A)50
Max Continuous Discharging Current (A)100
Battery Under Cut Alarm (V)24.2 (Settable)
Battery Under Cut (V)24 (Settable)
Float Charging Voltage (V)28.8
Boost Charging Voltage (V)28.8
Grid Charger
Grid Operating Voltage Range (V)120–280
Grid Frequency Range47–53
Ambient Conditions
Operating Temp (°C)0–50
Humidity95%
Degree of ProtectionIP 20
Cooling MethodTemp. Controlled FAN Force Cooling
Display/Indication
Protections PV – Reverse Polarity, High Current
Battery – Reverse Polarity, Under Voltage Cut, Over Voltage Cut
Grid – Over/Under Voltage, Over/Under Freq., Surge Protection, Reverse Feed Protection
Load – Overload, Short Circuit
Display Parameters PV: Voltage, Amps, Power, Today KWH, Total KWH Generation.
Battery: Voltage, Amps, Charge/Discharge Status
Grid: Voltage, Frequency
Load: Voltage, Load%, Frequency.
Load Operating Modes (UPS/Wide Range), Priority Selection, Grid Charging Enable/Disable, Battery Status (Charging/Discharging)
Display Faults PV: PV Over Voltage
Battery: Battery Under Voltage, Battery Over Voltage
Grid: Back Feed, Under/Over Voltage, Fuse Fail
Load: Overload, O/P Short Circuit
Scroll to Top